LionRock generator sets with Perkins, Cummins, MTU and Mitsubishi engines — for data centres, industrial facilities, telecom towers, and critical backup power. ISO9001 / ISO14001 / ISO45001 certified, CE marked. Soundproof enclosures, trailer mounting and parallel operation available.
Choose your engine brand based on performance tier, parts availability in your region, and project budget.
Perkins engines are the benchmark for commercial and light-industrial gensets — worldwide parts availability, proven reliability and competitive pricing. The LRP series covers the mainstream 10–1800 kVA range with single or parallel operation.
Best for: commercial buildings, light industry, healthcare →Cummins engines offer excellent power density and global service network coverage. The LRC series is a popular choice for data centres, industrial process equipment and large commercial properties where continuous-duty ratings are required.
Best for: data centres, industrial facilities, mining →MTU (Rolls-Royce Power Systems) engines set the benchmark for mission-critical applications. Tier 4 Final / Stage V capable, extremely low total cost of ownership, and designed for continuous 24/7 duty in demanding environments including data halls and marine installations.
Best for: mission-critical data centres, marine, oil & gas →Mitsubishi Heavy Industries engines are the preferred choice for Southeast Asian markets, with extensive regional service networks. The LRT series is widely used in water treatment, manufacturing, telecom and building services applications across ASEAN.
Best for: ASEAN projects, water treatment, telecom →Shanghai Diesel Engine Co. (SDEC / SAIC Motor) engines offer excellent value for budget-sensitive large-scale deployments. The LRSC series supports parallel operation of up to 32 units and is proven in large industrial parks, construction sites and telecommunications.
Best for: large arrays, industrial parks, cost-sensitive projects →Every LionRock generator set ships with the same baseline feature set regardless of engine brand.
Every LionRock genset is rated for 110% overload for 1 hour in any 12-hour period per ISO8528 — essential for peak demand events in data centres and industrial facilities.
All units ship with Leroy Somer (France) alternators with PMG (permanent magnet generator) excitation for stable voltage under non-linear loads — critical for UPS-backed IT equipment.
Integrated AMF panel detects mains failure and starts the generator automatically within 10 seconds. Manual, automatic and test modes standard. ATS integration available.
Optional acoustic canopy reduces noise to ≤75 dB(A) at 7 metres — suitable for urban locations, hospital campuses and residential-adjacent installations. Weatherproof IP23 minimum.
Synchronisation panels and droop governors enable N+1 redundancy with load sharing across multiple units. Arrays of up to 32 units tested and deployed in the field.
Major service interval of 2,000 engine hours (oil, filters, belts). Econo Solar supplies first-service spare parts kits in the initial FOB shipment upon request.
The 3TMElliott manufacturing plant holds all three ISO management system certifications. CE marking is standard on all units. Factory load-test certificates available per unit.
Mobile trailer-mounted and containerised (20ft / 40ft ISO) configurations available for temporary power, rental fleets and remote-site deployments without permanent infrastructure.
LionRock generator sets are in service across data centres, utilities, healthcare and large industrial facilities worldwide.
Primary and standby power for colocation and hyperscale data halls. N+1 parallel arrays with fast-start AMF. MTU and Cummins series preferred for continuous-duty ratings.
Process power for manufacturing plants, mining operations, oil & gas surface facilities and heavy industry where grid supply is unreliable or absent.
Standby power for mobile base stations, transmission nodes and submarine cable landing stations. Compact footprint and low-noise options for urban tower sites.
Hospital standby power, water treatment plants and emergency services infrastructure requiring certified reliability and rapid transfer within 10 seconds of mains failure.
Trailer-mounted rental-fleet units for construction sites, large events and emergency disaster-relief power. Containerised 20ft/40ft options for project sites without infrastructure.
Class-approved marine generator sets for vessel auxiliary power and offshore platform applications. MTU and Mitsubishi series with marine-grade alternators and seawater cooling.
LionRock generators are in service across data centres, utilities and government infrastructure projects in Asia, Southeast Asia, the Pacific and the Middle East.
Phase 1: 4 × 1,200 kW + 1 × 400 kW LionRock generator sets in soundproof enclosures for the primary data hall. Includes a 1.8 km thermal fuel rail storage system for extended autonomy. Phase 2 expanded to 6 × 1,200 kW to support additional compute density. N+1 parallel configuration with automatic load sharing and remote monitoring.
Supply and installation of 2 × 1,250 kVA / 1,000 kW LionRock generator sets for PCCW's enterprise data centre facility. Dual redundant fuel systems with day-tank and bulk-tank arrangement. Switchboard and power cable installation included. System provides N+1 backup power with automatic transfer switching fully integrated with the building management system.
Supply and installation of 2 × LRT40 and 2 × LRP250 generator sets for the Hong Kong Housing Authority Queens Hill development. Ongoing DLP (defects liability period) maintenance contract with monthly service visits. Tung Fong Housing Authority approved contractor status. All units tested to full rated load before handover.
Deployment of 22 × LRSC250 plus 2 × LRC205 LionRock generator sets in a parallel load-sharing configuration for a large industrial facility in the Philippines. Synchronisation panels and integrated load governors manage automatic load distribution across the 24-unit array. Remote SCADA monitoring with APAC regional support team.
Technical and procurement questions for B2B buyers and project engineers.
Send us your load requirement, engine preference and site details — we respond with configuration, datasheet and FOB pricing within 24 hours.