LV Withdrawable Switchgear
Modular, drawer-type low-voltage switchgear for AC 50Hz systems at 660V and below. Functional units rack in and out under load for maintenance without de-energizing neighboring feeders โ suited to larger PV plant low-voltage distribution rooms where uptime and modularity matter.
Datasheet-backed advantages for low-voltage distribution rooms where uptime and flexibility matter.
Functional units โ protection, operation, transfer, control, regulation, measurement and indication โ rack in and out as standardized drawers for maintenance without shutting down adjacent feeders.
C-type bar-section framework on a 25mm modulus, with over 200 standard components able to form different cabinet-frame and drawer-unit combinations.
Large use of high-strength, flame-retardant engineering plastic parts strengthens the protective safety performance of the assembly.
Beyond standard indoor duty, MNS can be specially treated for marine oil-drilling platforms and nuclear power stations under a separate technical agreement.
Parameters sourced from the manufacturer's MNS technical datasheet. Fields the source table does not state unambiguously are marked [DATA REQUIRED].
| Rated Working Voltage | 380 / 660 V |
|---|---|
| Rated Insulation Voltage | 660 / 1000 V |
| Rated Frequency | 50 Hz |
| Horizontal Busbar Rated Current | 630โ5000 A |
| Vertical Busbar Rated Current | 800โ2000 A |
| Vertical Bus Current โ Single/Double-Side Draw-Out MCC | 800 A |
| Vertical Bus Current โ 1000mm-Depth Single-Side MCC | 800โ2000 A |
| Horizontal Bus Rated Short-Time Withstand Current (rms) | 50โ100 kA |
| Horizontal Bus Rated Peak Withstand Current | 60โ130 kA |
| Vertical Bus Rated Short-Time Withstand Current (rms) | 105โ250 kA |
| Vertical Bus Rated Peak Withstand Current | [DATA REQUIRED] |
| Protection Degree (shell) | IP30, IP40 |
| Outline Dimension (H ร W ร D) | 2200 ร 600(800,1000) ร 800(1000) mm |
| Module Unit | 25 mm |
| Operating Ambient Temperature | โ5 ยฐC to +40 ยฐC (24h average โค +35 ยฐC) |
| Storage / Transport Temperature | โ25 ยฐC to +55 ยฐC (short-term โค24h up to +70 ยฐC) |
| Altitude | โค2000 m |
| Design Basis | Consulted from Switzerland ABB MNS series, manufactured with standard modules |
| Standards | IEC 60439-1 ยท GB 7251.1 |
Optimized for low-voltage distribution duty where modularity and maintainability matter most.
Central low-voltage distribution room serving multiple inverter stations, where drawer units allow feeder maintenance without a full plant shutdown.
Withdrawable feeder and motor-control units for large battery storage site auxiliary and HVAC loads, supporting hot maintenance.
Draw-out MCC configurations for pump, fan and compressor loads at hybrid solar-plus-generation or solar-plus-storage sites.
Reliable, maintainable low-voltage power for control rooms, SCADA systems and substation auxiliary equipment.
Datasheet-driven answers for procurement teams and switchgear designers.
Send your project size and drawer-unit schedule. We respond with configuration, lead time and FOB Shanghai pricing within 24 hours.