Epoxy Resin Vacuum-Cast, 6kV/10kV Distribution Class
Three-phase epoxy resin vacuum-cast dry-type transformer for PV plant step-up and general distribution applications. Manufactured using an automated vacuum pouring process with foil-wound high- and low-voltage windings for strong short-circuit withstand and low maintenance.
Manufacturer-stated advantages carried over from the epoxy-cast dry-type transformer platform.
Automatic vacuum pouring equipment follows a specific curing temperature curve; vertical pouring technology helps gas escape during casting and the equipment controls resin ratio and vacuum in real time.
Compared to impregnated-type windings, vacuum-cast construction gives stronger mechanical strength and short-circuit resistance, with a double-layer HV coil design that distributes impulse voltage evenly across the winding.
Foil winding construction reduces additional losses, achieves more uniform temperature distribution within the coil and improves short-circuit withstand versus wire-wound alternatives.
Seven-level stepped-joint core lamination and two-component high-temperature insulation varnish reduce losses, noise and vibration; the design is maintenance-free with a long service life.
Confirmed parameters are sourced from the manufacturer's SCB series documentation. Exact per-rating loss, current and impedance figures are confirmed per order — the source technical tables for these specific values contained OCR/formatting errors we could not reliably verify, so they are marked below rather than estimated.
| Type Designation | SC(Z)(B)□□-□□/□□-□□ (three-phase · epoxy potting · optional on-load tap changing · foil winding · performance level code · capacity kVA · HV kV · LV kV) |
|---|---|
| Series | SCB12 · SCB13 · SCB14 · SCB18 (performance level code varies by series) |
| Insulation Process | Epoxy resin vacuum pouring |
| Winding Type | Foil winding, HV and LV |
| Core Material | Cold-rolled grain-oriented silicon steel (Hi-B grain-oriented available on request) |
| Rated High Voltage | 6 / 6.3 / 6.6 / 10 / 10.5 / 11 kV |
| Rated Low Voltage | 0.4 kV |
| Tapping Range | ±5% or ±2×2.5% of HV (series-dependent) |
| Vector Group | Dyn11 · Yd11 · Yyn0 (series-dependent) |
| Rated Capacity Range | [DATA REQUIRED] — confirm exact kVA options for your required series/voltage at RFQ |
| No-Load Loss | [DATA REQUIRED] |
| Load Loss | [DATA REQUIRED] |
| No-Load Current | [DATA REQUIRED] |
| Short-Circuit Impedance | [DATA REQUIRED] |
| Insulation Class | [DATA REQUIRED] |
| Overload Monitoring | Embedded LV winding temperature sensors; automatic fan activation and alarm on rated response temperature |
| Noise Reduction Option | Hi-B core reduces noise by approx. 5–7 dB(A) vs. standard core |
| Protection Rating | [DATA REQUIRED] |
| Standards Compliance | GB/T 1094.1-2013 · GB/T 1094.3-2017 · GB/T 1094.5-2008 · GB/T 1094.10-2003 · GB/T 1094.11-2022 · GB/T 10228-2015 |
| Warranty | [DATA REQUIRED] |
General-purpose step-up and distribution applications for solar and mixed-use sites.
Standard step-up transformer between inverter/combiner output and the site's medium-voltage collection network on ground-mount and C&I PV plants.
Civil, industrial and infrastructure distribution scenarios including commercial centers, residential distribution networks and industrial/mining facilities, per the manufacturer's general product listing.
Positioned by the manufacturer as a maintenance-free, environmentally friendly replacement for oil-immersed distribution transformers.
Answers sourced from the manufacturer's SCB documentation.
Send your required capacity, voltage combination and vector group. We respond with stock, lead time and FOB Shanghai pricing within 24 hours.