Unit-Type AC Metal-Enclosed Ring Main Unit
Compact, SF6-insulated 12kV ring main unit built around a vacuum load switch, with interlocked incoming and outgoing cabinet schemes. Sized for ring-fed medium-voltage access points across a PV plant's collection network, where a full breaker lineup would be oversized.
Datasheet-backed advantages for compact ring-feeder access points.
Main switch and arc-quenching chamber are sealed in SF6 gas, giving a smaller footprint than air-insulated designs of equivalent rating.
The load switch, isolating knife and earthing knife share one interlocked frame, giving bus-connect, isolate and earth positions with a single, simple handle sequence.
The outgoing cabinet scheme adds a striker-fitted fuse acting as an automatic isolating switch — a fuse failure trips the load switch without operator action.
Insulating baffles interlocked with the earthing switch, plus mechanical interlocks between switch, baffle and door, meet the five-prevention standard with IP2X at internal switching compartments.
Parameters sourced from the manufacturer's HXGN□-12(SF6) technical datasheet. Fields the source table does not state unambiguously are marked [DATA REQUIRED].
| Rated Voltage | 12 kV |
|---|---|
| Rated Frequency | 50 Hz |
| Main Bus Bar Rated Current | 630 A |
| Fuse Breaker Max. Rated Current | 125 A |
| Main / Earthed Loop Short-Time Withstand Current | [DATA REQUIRED] |
| Main / Earthed Loop Rated Peak Withstand Current | 50 kA |
| Main / Earthed Loop Short-Circuit Making/Breaking Current | 50 kA |
| Load Switch Full-Capacity Operations | 100 operations |
| Fuse Breaker Opening Current | 31.5, 40 kA |
| Rated Closed-Loop Opening Current | 630 A |
| Rated Transfer Current | 1600 A |
| Mechanical Life | 2000 operations |
| 1-min Power-Frequency Withstand Voltage (to earth / across isolating gap) | 42 / 48 kV |
| Lightning Impulse Withstand Voltage, peak (to earth / across isolating gap) | 75 / 85 kV |
| Secondary Circuit 1-min Power-Frequency Withstand Voltage | 2 kV |
| Protection Degree | IP3X (enclosure) / IP2X (switching compartment) |
| Main Switch | ZFN□-10/630 vacuum load switch, SF6-insulated |
| Breaker Options | SFL-12/24 · ABB HAD/US SF6 · VD4-S vacuum |
| Operating Mode | Manual / Electric |
| Altitude | ≤2000 m |
| Operating Ambient Temperature | −25 °C to +40 °C |
| Storage Temperature | −30 °C to +40 °C |
| Standards | IEC 60298 · GB 3906 |
Optimized for compact medium-voltage ring access in solar and hybrid energy plants.
Compact tap points along a 12kV ring or loop collecting multiple inverter stations or transformer pads into a shared MV feeder.
Fused outgoing cabinet protects individual step-up or distribution transformers without the cost of a full circuit breaker cubicle.
Where substation footprint is constrained, the SF6-sealed unit replaces several air-insulated cubicles worth of ring access in one compact enclosure.
Ring-fed connection points for distributed battery storage blocks feeding into the same MV collection loop as the PV arrays.
Datasheet-driven answers for procurement teams and switchgear designers.
Send your single-line diagram. We respond with configuration, lead time and FOB Shanghai pricing within 24 hours.