AC Low-Voltage Fixed-Type Switchgear
Fixed-type, modular low-voltage switchgear for 380V AC 50Hz systems up to 3150A. A general-purpose, economical cabinet platform for power transfer, distribution and control — well suited to low-voltage AC combining and distribution ahead of the medium-voltage interconnection point.
Datasheet-backed advantages for low-voltage combining and distribution duty.
Cold-bent steel frame welded from standard bar steel sections, with a 20-module mounting-hole pattern for high component interchangeability across projects.
Ventilation slots sized to cabinet loading are built into the upper and lower ends of every frame to manage internal temperature rise during continuous operation.
Rotation-axis hinged doors with a rubber gasket strip compress against the frame on closing, preventing direct impact damage and raising the effective door protection grade.
Standard build is IP30; the same frame platform can be configured from IP20 up to IP40 to match indoor environmental conditions.
Parameters sourced from the manufacturer's GGD technical datasheet. Fields the source table does not state unambiguously are marked [DATA REQUIRED].
| Rated Voltage | 380 V AC |
|---|---|
| Rated Frequency | 50 (60) Hz |
| GGD1 Rated Current | 1000 / 600(630) / 400 A (as listed in source datasheet) |
| GGD2 Rated Current | 1500 / 1600 / 1000 A (as listed in source datasheet) |
| GGD3 Rated Current | 3150 (2500) / 2000 A (as listed in source datasheet) |
| GGD1 Rated Short-Circuit Breaking Current | 15 kA |
| GGD2 Rated Short-Circuit Breaking Current | 30 kA |
| GGD3 Rated Short-Circuit Breaking Current | 50 kA |
| GGD1 / GGD2 / GGD3 Rated Short-Time Withstand Current (1s) | 15 / 30 / 50 kA |
| GGD1 / GGD2 / GGD3 Rated Peak Withstand Current | 30 / 63 / 105 kA |
| Protection Degree | IP30 standard, selectable IP20–IP40 |
| Operating Ambient Temperature | −5 °C to +40 °C (24h average ≤ +35 °C) |
| Altitude | ≤2000 m |
| Installation | Indoor only |
| Cabinet Height (standard) | 2200 mm |
| Cabinet Width (by frame code) | 600 / 800 / 1000 / 1200 mm |
| Cabinet Depth (by frame code) | 450 / 650 / 850 / 1050 mm |
| Bus Bar Material | [DATA REQUIRED] |
| Standards | IEC 60439-1 · GB 7251.1 |
Optimized for low-voltage switching and distribution duty in solar and hybrid energy plants.
Combines multiple inverter AC outputs ahead of the plant's step-up transformer, within a single bolted, modular cabinet lineup.
General power and lighting distribution for inverter stations, O&M buildings and substation auxiliary loads.
Economical fixed-type LV switchboard for commercial and industrial PV sites where drawer-type withdrawability is not required.
Low-voltage distribution for battery storage block auxiliary systems — HVAC, fire suppression, lighting and controls.
Datasheet-driven answers for procurement teams and switchgear designers.
Send your project size and load schedule. We respond with configuration, lead time and FOB Shanghai pricing within 24 hours.